The importance of buffer and maintenance solutions could not be understated. These solutions should be used to initially calibrate all Hanna hand held meters and keep them working accurately for years.
The importance of buffer and maintenance solutions could not be understated. These solutions should be used to initially calibrate all Hanna hand held meters and keep them working accurately for years.
Waterproof pH/EC/TDS/Temperature Tester - 12880 Solution
The HI98130 Combo waterproof tester offers high accuracy pH, EC/TDS and temperature measurements all in a single tester! pH and EC/TDS readings are automatically compensated for the effects of temperature (ATC). These technologically advanced testers have a replaceable pH electrode cartridge with an extendable cloth junction as well as an EC/TDS graphite electrode that resists contamination by salts and other substances. Use solutions: 74-2535, 74-2540, 74-2536, 74-2525, 74-2530.
Range:
pH 0.00 to 14.00 pH EC 0.00 to 20.00 mS/cm
TDS 0.00 to 10.00 ppt Temp 0.0 - 60.0øC or 32.0 - 140.0øF
The HI98130 Combo waterproof tester offers high accuracy pH, EC/TDS and temperature measurements all in a single tester! pH and EC/TDS readings are automatically compensated for the effects of temperature (ATC). These technologically advanced testers have a replaceable pH electrode cartridge with an extendable cloth junction as well as an EC/TDS graphite electrode that resists contamination by salts and other substances. Use solutions: 74-2535, 74-2540, 74-2536, 74-2525, 74-2530.
Range:
pH 0.00 to 14.00 pH EC 0.00 to 20.00 mS/cm
TDS 0.00 to 10.00 ppt Temp 0.0 - 60.0øC or 32.0 - 140.0øF
The importance of buffer and maintenance solutions could not be understated. These solutions should be used to initially calibrate all Hanna hand held meters and keep them working accurately for years.
The importance of buffer and maintenance solutions could not be understated. These solutions should be used to initially calibrate all Hanna hand held meters and keep them working accurately for years.
The importance of buffer and maintenance solutions could not be understated. These solutions should be used to initially calibrate all Hanna hand held meters and keep them working accurately for years.
The importance of buffer and maintenance solutions could not be understated. These solutions should be used to initially calibrate all Hanna hand held meters and keep them working accurately for years.
This parameter is important in determination of the corrosive properties of water, caused by carbonates, bicarbonates as well as dissolved salts. Testing alkalinity is important in the treatment of soil and environmental testing as well as in agriculture. Range: 0-100 mg/L; 0-300 mg/L Smallest Increment: 1 mg/L; 3mg/L # of Test: 110
Temperature Meter with pH Electrode Diagnostic
*4 Meters in 1
*Fast response probe
*Slimline design
The 9813-6 has all popular features of the 9813, plus Cø and the New Cal-Check Calibration feature! Now you can verify a clean, calibrated electrode anywhere in seconds. Accuracy is ensured with Automatic Temperature Compensation (ATC) and an advanced sensor which completely eliminates polarization and oxidation problems. HANNA also developed F.S.T. technology for HI9813-6, with this special security system, a system failure will force a fixed value close to pH 4, rather than pH 7, and render the problem clearer to the user. Cal solutions: 74-2520, 74-2525, 74-2530, 74-2535, 74-2540.
Range:
pH 0.0 to 14.0
EC (mS/cm-mmho/cm) 0.00 to 4.00
TDS 0 to 1999 ppm (mg/L)
*4 Meters in 1
*Fast response probe
*Slimline design
The 9813-6 has all popular features of the 9813, plus Cø and the New Cal-Check Calibration feature! Now you can verify a clean, calibrated electrode anywhere in seconds. Accuracy is ensured with Automatic Temperature Compensation (ATC) and an advanced sensor which completely eliminates polarization and oxidation problems. HANNA also developed F.S.T. technology for HI9813-6, with this special security system, a system failure will force a fixed value close to pH 4, rather than pH 7, and render the problem clearer to the user. Cal solutions: 74-2520, 74-2525, 74-2530, 74-2535, 74-2540.
Range:
pH 0.0 to 14.0
EC (mS/cm-mmho/cm) 0.00 to 4.00
TDS 0 to 1999 ppm (mg/L)